When a new floor finish lifts, bubbles, opens at the joints or the adhesive stays soft, moisture in the screed or the base below is one of the first things to investigate. It is not the only possible cause, so find the source and test before relaying. A failed floor relaid on the same conditions is likely to fail again.

Symptoms that can point to moisture

  • Vinyl or LVT bubbling, lifting or joints opening.
  • Adhesive that stays soft or gives off an odour.
  • Timber cupping or swelling.
  • Tiles losing bond.
  • Resin coatings blistering.

Adhesive choice, preparation, temperature and the finish itself can produce similar symptoms. Treat the list as a reason to investigate, not a diagnosis.

Where can the moisture come from?

  • The screed itself: mixing water that has not yet dried out, particularly in thicker sections or a cold, closed building.
  • Below the screed: a missing, damaged or poorly lapped damp-proof membrane over a ground-bearing slab.
  • The building: wet trades, leaks or poor ventilation keeping humidity high. Water can also travel under skirtings, at door thresholds or through joints in an impermeable finish.
  • Heating: underfloor heating not commissioned as planned, so the drying assumed in the programme did not happen.

Was the floor tested, and how?

Ask which method was used, where, when and against which written acceptance criteria. RH hood readings, calcium carbide (CM) results and electronic meter scales measure different things and are not interchangeable. F. Ball’s hygrometer guidance references BS 8203 for resilient floorcoverings, BS 5325 for textile floorcoverings and BS 8201 for wood floorcoverings. The screed, adhesive and flooring manufacturers set the limits that apply to their system. Our guide to moisture tests explains the differences.

Can a surface DPM solve it?

Sometimes. A surface DPM is applied to the screed to hold back residual moisture so a finish can go down sooner. Each product states the substrates it suits, the moisture conditions it can handle and the primer and smoothing system required. It is not a substitute for finding and fixing water coming from a failed membrane or a leak, and on calcium sulphate screeds the product must be approved for that base. The screed surface usually needs preparation, including removal of laitance where the manufacturer requires it, so the DPM can bond. Follow the DPM, adhesive and flooring manufacturers’ written guidance.

At Emanuel School, a surface DPM formed part of the specified floor build-up, followed by primer and levelling compound before the finish.

Already failed? What to do

  1. Record the symptoms with photos, locations and dates.
  2. Lift a representative section and check the adhesive and the screed surface.
  3. Agree a test plan for the screed and base, including likely wetter areas.
  4. Identify the moisture source before choosing a remedy.
  5. Put the findings and the agreed remedy in writing before relaying.

A lesson from a failed sports hall floor

At Uxbridge College, a moisture test was taken before the product’s drying period was complete, and a surface DPM was then applied across a large area under programme pressure. In the changing area, vinyl later bubbled and lifted. The adhesive had become wet, and there was no reliable record that the finish had been tested and accepted before it was laid. The lesson is practical: test at the right time, record the method and result, and do not relay a finish until the moisture source is understood.

How to prevent it next time

  1. Plan drying time from the product data when the programme is set.
  2. Get the building weathertight and ventilated.
  3. Commission underfloor heating to the manufacturer’s procedure and record it.
  4. Agree the test method, locations and acceptance criteria before the flooring date.
  5. Give the flooring contractor the results in writing.

Frequently asked questions

Why is my new vinyl floor bubbling?

Moisture breaking down the adhesive is a common reason, but preparation, temperature and adhesive choice can also contribute. Investigate and test before relaying.

Can you lay flooring on a damp screed?

Only where the flooring system allows it, for example with a suitable surface DPM used within its manufacturer’s limits. Follow the written guidance for the whole system.

How do I know the screed is dry enough?

Test it with the method the flooring system accepts and compare the result with that system’s written criteria. A surface that looks dry is not a test.

Who pays when flooring fails on a damp screed?

That depends on the contract and the records, particularly whether moisture was tested and accepted in writing before the finish went down.

What to do next

If a floor is failing, or about to be covered, send us your drawings and we can discuss the testing scope. A test request is not a guarantee that the floor will pass.